| Generic Part Number | Package | Marketing Status | General Description | Hold Current(I_h) | Peak Repeat Off Voltage(VDRM) | Peak Repeat Reverse Voltage(VRRM) | Peak I Cycle Surge On Current(ITSM) | Peak On Voltage(VTM) | Gate Trigger Voltage(I_GT) | Gate Non-Trigger Voltage(VGD) | Rising Ratio Of Off Voltage(dv/dt) | Latching Current(IL) | Thermal Resistance(junction To Ambient)(R_th(J-A)) | Thermal Resistance(junction To Ambient)(R_th(J-A)) | 数据手册Datasheet下载 |
| min | max | max | max | max | nom | nom | min | nom | nom | max | |||||
| A | V | V | A | V | V | V | V/s | A | °C/W | °C/W | |||||
| ACS102-6T | SO8; TO 92 S.SIG PLASTIC LEADS IN ROW | Active | Transient protected AC switch (ACS™) | 0.02 | 600 | 600 | 7.3 | 1.2 | 0.9 | 0.15 | 300 | 0.025 | 150 | - | ACS102-6T |
| ACS108-6S | SOT 223 PLANAR and TOPGLASS; TO 92 S.SIG PLASTIC LEADS IN ROW | Active | Transient protected AC switch (ACS™); Transient voltage protected AC Switch (ACS™) | 0.025 | 600 | 600 | 7.3 | 3 | 1 | 0.15 | 500 | 0.03 | 60.0-150.0 | - | ACS108-6S |
| ACS110 | PDIP8; SOT 223 PLANAR and TOPGLASS | Active | AC LINE SWITCH | 0.045 | 700 | 700 | 8 | 1.3 | 1 | 0.15 | 500 | 0.065 | 60 | 60 | ACS110 |
| ACS120 | IPAK TO-251; TO 220 AB NON ISOL; TO 220 ISOL FULL PACK 0.5 AB; TO 252 DPAK | Active | AC LINE SWITCH | 0.045 | 700 | 700 | 20 | 1.3 | 1 | 0.15 | 500 | 0.065 | 60.0-70.0 | 70 | ACS120 |
| ACS302 | SO20 | Active | THREE LINES AC SWITCH ARRAY | 0.02 | 500 | 500 | 7.3 | 1.2 | 0.9 | 0.15 | 300 | 0.025 | 93 | 93 | ACS302 |
| ACST10 | TO 220 AB NON ISOL; TO 220 ISOL FULL PACK 0.5 AB | Active | - | 0.012 | 700 | 700 | 100 | 1.5 | - | 0.2 | - | 0.05-0.07 | 60 | - | ACST10 |
| ACST12 | D2PAK DOUBLE TRACK; TO 220 AB NON ISOL | Active | - | 0.012 | 700 | 700 | 120 | 1.5 | - | 0.2 | - | 0.05-0.07 | 60 | - | ACST12 |
| ACST2 | TO 220 ISOL FULL PACK 0.5 AB; TO 252 DPAK | Active | Alternating current switch | 0.01 | 800 | 800 | 8 | 2 | 1.1 | 0.2 | 500 | 0.025 | 60 | - | ACST2 |
| ACST4 | IPAK TO-251; TO 220 ISOL FULL PACK 0.5 AB; TO 252 DPAK | Active | AC POWER SWITCH | 0.02 | 700 | 700 | 30 | 1.5 | 1.0-1.1 | 0.2 | 200 | 0.04-0.06 | 60.0-70.0 | 70 | ACST4 |
| ACST6 | D2PAK DOUBLE TRACK; I2PAK DT; TO 220 AB NON ISOL; TO 220 ISOL FULL PACK 0.5 AB | Active | OVER VOLTAGE PROTECTED AC POWER SWITCH | 0.025 | 700 | 700 | 45 | 1.4 | 1.5 | 0.2 | 200 | 0.05 | 45.0-60.0 | 60 | ACST6 |
| ACST8 | D2PAK DOUBLE TRACK; TO 220 AB NON ISOL; TO 220 ISOL FULL PACK 0.5 AB | Active | OVER VOLTAGE PROTECTED AC POWER SWITCH | 0.04 | 800 | 800 | 80 | 1.5 | 1.5 | 0.2 | 750 | 0.07 | 60 | 60 | ACST8 |
| STCC08 | SO8 | Active | AC switch failure mode detector | - | - | - | - | - | - | - | - | - | 140 | - | STCC08 |