Generic Part Number |
Package |
Marketing Status |
General Description |
Hold Current(I_h) |
Peak Repeat Off Voltage(VDRM) |
Peak Repeat Reverse Voltage(VRRM) |
Peak I Cycle Surge On Current(ITSM) |
Peak On Voltage(VTM) |
Gate Trigger Voltage(I_GT) |
Gate Non-Trigger Voltage(VGD) |
Rising Ratio Of Off Voltage(dv/dt) |
Latching Current(IL) |
Thermal Resistance(junction To Ambient)(R_th(J-A)) |
Thermal Resistance(junction To Ambient)(R_th(J-A)) |
数据手册Datasheet下载 |
min |
max |
max |
max |
max |
nom |
nom |
min |
nom |
nom |
max |
A |
V |
V |
A |
V |
V |
V |
V/s |
A |
°C/W |
°C/W |
ACS102-6T |
SO8; TO 92 S.SIG PLASTIC LEADS IN ROW |
Active |
Transient protected AC switch (ACS™) |
0.02 |
600 |
600 |
7.3 |
1.2 |
0.9 |
0.15 |
300 |
0.025 |
150 |
- |
ACS102-6T |
ACS108-6S |
SOT 223 PLANAR and TOPGLASS; TO 92 S.SIG PLASTIC LEADS IN ROW |
Active |
Transient protected AC switch (ACS™); Transient voltage protected AC Switch (ACS™) |
0.025 |
600 |
600 |
7.3 |
3 |
1 |
0.15 |
500 |
0.03 |
60.0-150.0 |
- |
ACS108-6S |
ACS110 |
PDIP8; SOT 223 PLANAR and TOPGLASS |
Active |
AC LINE SWITCH |
0.045 |
700 |
700 |
8 |
1.3 |
1 |
0.15 |
500 |
0.065 |
60 |
60 |
ACS110 |
ACS120 |
IPAK TO-251; TO 220 AB NON ISOL; TO 220 ISOL FULL PACK 0.5 AB; TO 252 DPAK |
Active |
AC LINE SWITCH |
0.045 |
700 |
700 |
20 |
1.3 |
1 |
0.15 |
500 |
0.065 |
60.0-70.0 |
70 |
ACS120 |
ACS302 |
SO20 |
Active |
THREE LINES AC SWITCH ARRAY |
0.02 |
500 |
500 |
7.3 |
1.2 |
0.9 |
0.15 |
300 |
0.025 |
93 |
93 |
ACS302 |
ACST10 |
TO 220 AB NON ISOL; TO 220 ISOL FULL PACK 0.5 AB |
Active |
- |
0.012 |
700 |
700 |
100 |
1.5 |
- |
0.2 |
- |
0.05-0.07 |
60 |
- |
ACST10 |
ACST12 |
D2PAK DOUBLE TRACK; TO 220 AB NON ISOL |
Active |
- |
0.012 |
700 |
700 |
120 |
1.5 |
- |
0.2 |
- |
0.05-0.07 |
60 |
- |
ACST12 |
ACST2 |
TO 220 ISOL FULL PACK 0.5 AB; TO 252 DPAK |
Active |
Alternating current switch |
0.01 |
800 |
800 |
8 |
2 |
1.1 |
0.2 |
500 |
0.025 |
60 |
- |
ACST2 |
ACST4 |
IPAK TO-251; TO 220 ISOL FULL PACK 0.5 AB; TO 252 DPAK |
Active |
AC POWER SWITCH |
0.02 |
700 |
700 |
30 |
1.5 |
1.0-1.1 |
0.2 |
200 |
0.04-0.06 |
60.0-70.0 |
70 |
ACST4 |
ACST6 |
D2PAK DOUBLE TRACK; I2PAK DT; TO 220 AB NON ISOL; TO 220 ISOL FULL PACK 0.5 AB |
Active |
OVER VOLTAGE PROTECTED AC POWER SWITCH |
0.025 |
700 |
700 |
45 |
1.4 |
1.5 |
0.2 |
200 |
0.05 |
45.0-60.0 |
60 |
ACST6 |
ACST8 |
D2PAK DOUBLE TRACK; TO 220 AB NON ISOL; TO 220 ISOL FULL PACK 0.5 AB |
Active |
OVER VOLTAGE PROTECTED AC POWER SWITCH |
0.04 |
800 |
800 |
80 |
1.5 |
1.5 |
0.2 |
750 |
0.07 |
60 |
60 |
ACST8 |
STCC08 |
SO8 |
Active |
AC switch failure mode detector |
- |
- |
- |
- |
- |
- |
- |
- |
- |
140 |
- |
STCC08 |