Multiple Cell Li+/Polymer Battery Charger
型号 Input Voltage Range (V) Input Current Limit Accuracy (%) Battery Charge Voltage (V) Charging Voltage Accuracy (max) (%) Battery Charge Voltage Adjust (%) Charge Current Limit Accuracy (%) Trickle Charge Current Limit Accuracy (%) Automatic Trickle Charge (typ) (V) Battery Leakage Current (max) (礎) Automatic Power Source Selection DC Adapter Detection Topology Switching Frequency (typ) (kHz) Max Duty Cycle (%) Audible Noise Operating Temp. Range (癈) Thermal Shutdown (癈) 1K Units MSRP ($)
ISL6251 7 to 25 3 4.2/Cell (2S, 3S, 4S) 0.5 5/Cell 5 (CHLIM=2.0V) 50 (CHLIM=0.2V) No (Set by Host) 10 (DCIN=0V, No System Load) No No Fixed Frequency Synchronous Buck 300 99.9 No -10 to 100 150 3
ISL6251A 7 to 25 3 4.2/Cell (2S, 3S, 4S) 0.5 5/Cell 3 (CHLIM=2.0V) 25 (CHLIM=0.2V) No (Set by Host) 10 (DCIN=0V, No System Load) No No Fixed Frequency Synchronous Buck 300 99.9 No -10 to 100 150 3
ISL6252 7 to 25 3 4.2/Cell (2S, 3S, 4S) 0.5 5/Cell 3 (CHLIM=2.0V) 25 (CHLIM=0.2V) No (Set by Host) 10 (DCIN=0V, No System Load) No No Fixed Frequency Synchronous Buck 300 99.6 No -10 to 100 150 3.8
ISL6252A 7 to 25 3 4.2/Cell (2S, 3S, 4S) 0.5 5/Cell 3 (CHLIM=2.0V) 25 (CHLIM=0.2V) No (Set by Host) 10 (DCIN=0V, No System Load) No No Fixed Frequency Synchronous Buck 300 99.6 No -10 to 100 150 3.8
ISL6253 7 to 25 3 4.2/Cell (2S, 3S, 4S) 0.6 5/Cell 3 (CHLIM=3.3V) 35 (CHLIM=3.3V) Yes (3.1/Cell) 10 (DCIN=0V, No System Load) Yes Yes Fixed Frequency Synchronous Buck 300 99.9 No -10 to 100 150 2.26
ISL6255 7 to 25 3 4.2/Cell (2S, 3S, 4S) 0.5 5/Cell 5 (CHLIM=2.0V) 50 (CHLIM=0.2V) No (Set by Host) 10 (DCIN=0V, No System Load) Yes Yes Fixed Frequency Synchronous Buck 300 99.9 No -10 to 100 150 3.93
ISL6255A 7 to 25 3 4.2/Cell (2S, 3S, 4S) 0.5 5/Cell 3 (CHLIM=2.0V) 25 (CHLIM=0.2V) No (Set by Host) 10 (DCIN=0V, No System Load) Yes Yes Fixed Frequency Synchronous Buck 300 99.9 No -10 to 100 150 3.11
ISL6256 7 to 25 3 4.2/Cell (2S, 3S, 4S) 0.5 5/Cell 3 (CHLIM=2.0V) 25 (CHLIM=0.2V) No (Set by Host) 10 (DCIN=0V, No System Load) Yes Yes Fixed Frequency Synchronous Buck 300 99.6 No -10 to 100 150 3.93
ISL6256A 7 to 25 3 4.2/Cell (2S, 3S, 4S) 0.5 5/Cell 3 (CHLIM=2.0V) 25 (CHLIM=0.2V) No (Set by Host) 10 (DCIN=0V, No System Load) Yes Yes Fixed Frequency Synchronous Buck 300 99.6 No -10 to 100 150 3.93
ISL6257 7 to 25 1.5 4.2/Cell (2S, 3S, 4S) 0.5 5/Cell 1.5 (CHLIM=2.0V) 25 (CHLIM=0.2V) No (Set by Host) 10 (DCIN=0V, No System Load) No (Set by Host) Yes Fixed Frequency Synchronous Buck 300 99.9 No -10 to 100 150 3.42
ISL6258 7 to 25 3 6.144 to 19.2 in 16mV Steps 0.5 16mV Steps 3 128mA to 384mA Yes (Threshold Set by User) 25 (DCIN=0V, No System Load) Yes No Fixed Frequency Synchronous Buck 400 99.9 No -10 to 100 150 4.22
ISL6258A 7 to 25 3 6.144 to 19.2 in 16mV Steps 0.5 16mV Steps 3 128mA to 384mA Yes (Threshold Set by User) 25 (DCIN=0V, No System Load) Yes No Fixed Frequency Synchronous Buck 400 99.9 No -10 to 100 150 4.22
ISL88731 7 to 25 3 2.7 to 19.2 in 16mV Steps 0.5 16mV steps 3 64mA to 220mA 2.7 2 (DCIN=0V, No System Load) No (Set by Host) No (Set by Host) Fixed Frequency Synchronous Buck 400 99.9 No -10 to 100 150 4.07
ISL9518 8 to 22 ±3 1.024 to 19.2 in 16mV Steps 0.5 16mV steps 3 128mA to 384mA 4.5 25 (DCIN=0V, No System Load) Yes Yes Adj Frequency Buck 400, 100, 50 90 No -10 to 100 150 6.33
ISL9518A 8 to 22 ±3 1.024 to 19.2 in 16mV Steps 0.5 16mV steps 3 128mA to 384mA 4.5 25 (DCIN=0V, No System Load) Yes Yes Adj Frequency Buck 400, 100, 50 90 No -10 to 100 150 6.33